Stokerx Beta 0.2 Release
About this release BETA CAE Systems S.A. Announces the release of the maintenance version 16.0.2 of its software suite. This maintenance release is focused on the correction of identified problems and issues for the ANSA and META software of the BETA CAE Systems suite v16.0x branch, for those who have not migrated to the v16.1x branch yet. The 16x version of the ANSA pre- processor provides full compatibility with previous major versions.
An incremental update is rolling out to OnePlus 3 and OnePlus 3T owners - OxygenOS 4.0.2 and a new beta update for each device.
As with every major release, a broad range of new features and enhancements to existing ones add value to our solutions, reinforce overall process consistency, accelerate user performance, and provide a considerable boost on productivity. The EPILYSIS solver is the new addition to the BETA CAE Systems analysis tools family and is available with the ANSA / EPILYSIS / META suite. Named after the Greek word for solution, it operates as a solution in the field of Finite Element Analysis embodying the accumulated knowledge from 25 years of collaboration with the CAE community. EPILYSIS covers numerous solution types and intends to bridge the gap between pre- and post- processing for disciplines such as Structural, NVH, Optimization, and more. The v16x version of the µETA post-processor builds upon the tools available in previous releases, now supporting an increased array of new interfaces including EPILYSIS, the in-house solver of BETA CAE Systems, as well as enhancing the multi-disciplinary tools. The most important additions and fixes implemented in v16.0.2 are listed below.
Understanding the Software Release Schedule The plan We are committed in delivering improved and enhanced software releases, the soonest possible, in order to meet the requirement of our customers for the continuous improvement of their experience and work. Therefore, we are working in releasing new software versions with code corrections, new software features and enhancements, in regular, frequent intervals. A major software version is released every year.
First point releases, such as v16.0.0, v16.1.0, v16.2.0 and so on, with code corrections but also with additional software features and enhancements are released every three months. Second point releases, such as v16.0.1, v16.0.2 etc. Mainly with code corrections only upon their parent first point release, are scheduled on a monthly basis.
Each software release is accompanied by a detailed description of the introduced corrections and/or additions so that our customers can decide whether it is critical to implement this release in their environment. This release This release of v16.0.2 brings additional features and code corrections on v16.0.x. Known issues resolved in ANSA General Launch: The default starting.sh script in Linux machines has been modified to search both for lockfile and socket instead of only lockfile. Clicking twice inside the 'List of Coordinate Systems to Compress' window, could resulted in unexpected termination. In some cases, Laminates would be illustrated with an improper offset position. Scripting ExtractCrossSectionsFromPlane: Running the function in nogui mode, resulted in unexpected termination. Output: The “userelativenameforreadonlyincludes” option of an output script function (eg.,OutputNastran ), would not be applied.
CAD Import / Export CATIA Working planes in CATIA files would be converted to Faces during import in ANSA. Connections and Assembly In certain cases the realization of Seam Lines Y-JOINT-SHELL would fail if affected elements belonged to Morphing Boxes. Meshing Save As: Attempting to save a copy from a compressed database (.ansa.gz) would result in a non-compressed file. Elements Wrap Variable Length: The “Scale Base Length” option might not be respected by the procedure. Refine: Trias function would not apply on Linked Faces. Solver Interfaces OptiStruct: New parameters are now supported through OptiStruct output function.
LS-DYNA: The Spot Welds Checks procedure might ignore Contact of Type TIEDSHELLEDGETOSURFACEOFFSET. Simulayt: Layup files output by ANSA, could not be read in by Primer due to a missing field on the 202 lines. For more details about the new software features, enhancements and corrections please, refer to the Release Notes document.
Known issues resolved in META Supported Interfaces Parts might not be positioned correctly for Abaqus files with the.NMAP keyword. Nodal thickness would not be read for Abaqus files with initial temperature defined. Results of cyclic symmetry analyses might not be read correctly from ANSYS.rst files. Reading FEMZIP-compressed ERF files could cause unexpected termination. Scanning results from Medina files could cause unexpected termination.
Reading results from Optistruct.h3d files could cause unexpected termination. Complex GPFORCE curves from Optistruct.pch files might not be read correctly.
Reading OpenFOAM cellzone results could lead to unexpected termination. RADIOSS models with /PROP/CONNECT were not read correctly, leading to wrong material assignment. Model geometry might not be correctly read from RADIOSS gzip-compressed files. Scalar results would not be read from certain StarCCM+.ccm files. General In certain cases annotations on curves would not point correctly or display correct values.
Stokerx Beta 0.2 Release Date
Unexpected block when applying Strain Gauges on LS-DYNA models with RigidWalls. Reading certain.pptx files in the Report Composer might cause unexpected termination.
Math Operations on Field Data Unexpected termination could occur when selecting multiple states created by the User Field Function tool. Selecting a curve as a load history in the Linear Combination tool, could cause unexpected termination. The Linear Combination tool might not work for composite results. Managing Curve Data Plotting time history results for user defined variables could cause unexpected termination. Reloading compressed & simplified.metadb files could result in unexpected termination.
Curves read from LS-DYNA elout files would have the same points 5 times. Projects Unexpected termination could occur when overlaying META Projects without references to files. Reading and saving directly a Project file could cause unexpected termination.
Results loaded using the Cut-Off option of Read Results card might not be saved correctly in Projects. For more details about the new software features, enhancements and corrections please, refer to the Release Notes document.
Compatibility and Supported Platforms ANSA files saved by all the first and second point releases of a major version are compatible to each other. New major versions can read files saved by previous ones but not vice versa. META Project files saved from version 16.0.2 are compatible and can be opened by META version 16.0.0 or later. To be readable by META versions earlier than v16.0.0, they have to be saved selecting the option 'Version.
. Added support for Intel Sandy Bridge CPU core temperature and clock sensors. Added support for core temperature and clocks of AMD Fusion (14h family) and family 11h CPUs. Fixed the core temperature reading on older revisions of AMD K8 CPUs (family 0Fh). Corrected the bus and core clock reading on Pentium 4 CPUs.
Improved the CPU clock reading accuracy. New SSD support and wear level sensors for Intel, Indilinx, SandForce and Samsung drives. Added support for manual fan control on ATI/AMD GPUs. Improved the support for reading sensors on GPUs in Crossfire mode. Added support for Nuvoton NCT6771F and NCT6776F super I/O chips.
Fixed fan speed reading on older revision of IT8712F super I/O chips. Added a mainboard specific configuration for the ASUS P8P67 Pro, ASRock P55 Deluxe and ASRock AOD790GX-128M. Added a “Reset” command to the menu, which allows to restart the sensor reading implementation without exiting the application. Fixed a few bugs in the Heatmaster and T-Balancer implementation. Reimplemented the device driver management code and improved the security. Added the global flag to the AccessISABUS.HTP.Method mutex.
Fixed the reseting of min and max values of HDD temperatures. Fixed some scaling errors that occured when using 125% or 150% text size in Windows. The main window can now be opened by double clicking the desktop gadget. Improved the moving and resizing of the gadget on multi-monitor systems. Added a WMI interface to provide all the sensor data to other applications and tools.
Fixed a few problems with saving and restoring the main window position and size. Added basic CPU support for Linux systems. Added support for AMD K10 (family 10h) core temperature sensors and Asus ATK0110 devices on Linux systems.
Comments are closed.